FLUKE LINKRUNNER MANUAL PDF

Validate up to 30W Verify twisted-pair cable length and wire-map in a snap. Automate reporting and enable collaboration with upload and management test results via Link-Live Cloud Service. Test results can be automatically uploaded to the Link-Live Cloud Service to improve collaboration between network engineers and technicians, creating greater job visibility, project control, and fleet management. It performs an essential set of network connectivity tests, enabling you to quickly and accurately identify and solve network connectivity problems. Switch Allows you to quickly validate switch connectivity and configuration.

Author:Zulkinris Fegor
Country:Dominica
Language:English (Spanish)
Genre:Marketing
Published (Last):5 August 2016
Pages:17
PDF File Size:5.6 Mb
ePub File Size:19.64 Mb
ISBN:556-6-63777-210-4
Downloads:92019
Price:Free* [*Free Regsitration Required]
Uploader:Kazibei



All product names are trademarks of their respective companies. The warranty period for the mainframe is one year and begins on the date of purchase. Parts, accessories, product repairs and services are warranted for 90 days, unless otherwise stated. Fluke Networks warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke Networks does not warrant that software will be error free or operate without interruption.

Fluke Networks authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke Networks.

Warranty support is available only if product is purchased through a Fluke Networks authorized sales outlet or Buyer has paid the applicable international price. Fluke Networks warranty obligation is limited, at Fluke Networks option, to refund of the purchase price, free of charge repair, or replacement of a defective product which is returned to a Fluke Networks authorized service center within the warranty period. To obtain warranty service, contact your nearest Fluke Networks authorized service center to obtain return authorization information, then send the product to that service center, with a description of the difficulty, postage and insurance prepaid FOB destination.

Fluke Networks assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid FOB destination. If Fluke Networks determines that failure was caused by neglect, misuse, contamination, alteration, accident or abnormal condition of operation or handling, or normal wear and tear of mechanical components, Fluke Networks will provide an estimate of repair costs and obtain authorization before commencing the work.

Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges FOB Shipping point.

Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision.

The software license statement and files that contain the binary and source code for freeRTOS v6. All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. Neither the name of the University of California, Berkeley nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission.

Contents Title Page Introduction Physical Features The Home Screen How to Remove the Battery Tools Menu IP Configuration Screen AutoTest Configuration Screen PoE Configuration Screen Connect Configuration Screen General Configuration Screen Reflector Settings Screen Reflector Default Configuration Screen LinkRunner Information Screen AutoTest Results Screen Expanding Test Results Nearest Switch Results Cable Test Results Fiber Connected Switch Results In addition, the tester can be used for identifying the network device to which it is connected.

It identifies PoE ports, provides a Report generating function, and can serve as a packet reflector for Fluke Networks performance tests. You can also transfer and view reports on LinkRunner Manager. Registering your product with Fluke Networks gives you access to valuable information on product updates, troubleshooting procedures, and other services. The Fluke Networks Knowledge Base The Fluke Networks Knowledge Base gives answers to common questions about Fluke Networks products and includes information on technology and procedures for network and cable tests.

Safety Information Table 1 gives descriptions of the safety symbols used on the tester and in this manual. Table 1. Warning: Risk of electrical shock. Do not put products that contain circuit boards into waste containers. Refer to local regulations for disposal procedures. See explanations in the manual. Before using the product, inspect the case. Look for cracked or missing plastic. Do not look into the laser port because this may cause eye injury. UnpackingWCautions Use the proper terminals and cable for all connections.

If something is damaged or missing, tell the dealer where you purchased the product. To clean the case, use a soft cloth that is moist with water or a weak soap. WCaution To prevent damage to the display or the case, do not use solvents or abrasive materials. The function of the softkey is shown above the key. Connect the cable from the top Ethernet port to this port to view the wire map details. Use one of the many supported SFP adapters to connect to the network.

The LED is red when the battery is charging and green when the battery is fully charged. When the battery charge is low, the icon blinks. Connect the ac adapter to charge the battery and to make sure the tester continues to operate. Shows that the ac adapter is connected. Shows that the USB interface is connected. This can also be used to locate a cable with the optional IntelliToneTM probe.

A profile contains the tester configuration settings. The name shows an asterisk to the right of the name if you have changed a setting on the tester since you loaded or saved the profile.

When no port is specified, a Ping is performed. This is also referred to as a TCP Connectivity test. For Battery Charging and Life To charge the battery, connect the ac adapter to the battery connector see Figure 1. You can use the tester while you charge the battery. Figure 3 shows how to replace the battery.

When the tester is off, the battery charges in approximately 3 hours. Note The battery will not charge if the internal temperature of the tester is above oF 45oC.

The battery life is approximately 6 hours during typical operation. An icon in the upper-left corner of the screen shows the battery status. How to Remove the Battery , Check the following list of questions and associated answers to see how LinkRunner AT can help you get the job done. Use AutoTest to observer the acquired IPv6 link-local and global address. Configure an address and application port e.

The LR-AT model can save up to 50 reports. To save the measurement data collected on the tester: 1 Press P. The tester shows a default filename at the bottom of the screen. The tester saves the data into a report file. Note Report names can have a maximum of 12 characters. To view the report, open it in LinkRunner Manager. Refer to the LinkRunner Manager help for instructions.

Set Up the Tester To change settings on the tester, select Tools from the home screen. This applies to the Switch and Cable test screens. This screen also allows you to enable and enter a user defined MAC address. AutoTest Configuration Screen This screen allows you to enter up to ten key device addresses Targets to test connectivity.

The Continuous Mode check box allows the test to run continuously checked or one time un-checked. When you exit the AutoTest screen, the test is stopped. If you enable PoE and select Class 4 TruePowerTM puts a load on the PoE device and gives an accurate measurement on whether the device supports the Class selected. Connect Configuration Screen This screen allows you to enable Only one certificate can be installed on a LR-AT at a time.

The default or pre-configured Reflector settings are displayed below ffy Reflector Settings Screen Select Configure.

GTC ISO TR 10013 PDF

FLUKE NETWORKS LINKRUNNER AT 2000 (01) PDF MANUAL

.

ENFERMEDAD DE WISKOTT ALDRICH PDF

Fluke LinkRunner Duo Quick Reference Manual

.